2024.1 Release Notes PDF
PC-DMIS 2024.1 Highlights :
Improved integration with Nexus Metrology Reporting
Streamlined data uploads Metrology Reporting for easier collaboration and faster decision-making
PC-DMIS ECO Mode
Save energy – power down your CMM and program offline or access PC-DMIS during maintenance
QIF CAD PMI data enhancements
Improved support for QIF file format – now access CAD assembly details
Mesh & Pointcloud enhancements
Export cross sections in XYZ or IGES formats, review vector information for Surface Normals
Geometric Tolerance now supports ISO codes
Save time by adding an ISO tolerance code rather than entering values
ClearanceCube improvements
Fast access to ClearanceCube settings directly from the Summary mode
Renishaw Equator workflow improvements
A streamlined, script free experience and new custom commands direct from the toolbar
In addition to the new features and improvements mentioned in the summary, PC-DMIS 2024.1 also includes:
Angle Feature extracts laser studs
Use the Angle Filter when extracting Laser Auto Feature Studs. Solves issues generated by over scanning the flat area surrounding cylinders.
Extended Sheet Metal Features (ESF) supports COP operators for optical feature extraction
Extract Optical ESF features from COP operators: Select, Filter, Cross Section
HP-L Laser patch scan as freeform
Create a Laser Patch scan as a freeform scan. Freeform scans reduce execution time
Change colour of HP-L Laser working area [idea centre]
Make the Laser working area more visible regardless of the color of the CAD model and the background color in the Graphics Display window
Vertical clipping independent values for laser features extraction
The nominal calculation of the Flush has been improved. Users can now set independent up and down values for vertical clipping, fine tuning the extraction to exclude unwanted data
Laser Auto Features flush nominal calculation
Improved accuracy and alignment with ESF (VWMP). Users can now choose to program Auto Features and ESF (VWMP) for Flush and Gap measurement – this helps to provide consistent nominals.
Search within collapsed group
PC-DMIS will search through a collapsed group and expand the group to show where the string is found – it highlights the term in the command window.
INFO | NAME | SIZE |
---|---|---|
<DIRECTORY> | Chinese_Simplified | N/A |
<DIRECTORY> | Chinese_Traditional | N/A |
<DIRECTORY> | Czech | N/A |
<DIRECTORY> | Dutch | N/A |
<DIRECTORY> | English | N/A |
<DIRECTORY> | French | N/A |
<DIRECTORY> | German | N/A |
<DIRECTORY> | Hungarian | N/A |
<DIRECTORY> | Italian | N/A |
<DIRECTORY> | Japanese | N/A |
<DIRECTORY> | Korean | N/A |
<DIRECTORY> | Polish | N/A |
<DIRECTORY> | Portuguese | N/A |
<DIRECTORY> | Russian | N/A |
<DIRECTORY> | Spanish | N/A |
<DIRECTORY> | Swedish | N/A |
<DIRECTORY> | Turkish | N/A |
PC-DMIS 2024.1 Recommended System Requirements :
PC Hardware, OS, and other connectivity needs
Operating system
PC-DMIS 2024.1 operates under 64-bit Windows 11, Windows 10. No other operating systems are supported.
Starting with RDS version 6.3, the Windows 11 operating system is supported.
- For HP-L systems and systems that use RS-SQUARED sensors that run PC-DMIS in DCC mode, you need to use a 64-bit Windows 10 Pro Computer with up to 4 Cores. You can find a list of supported operating systems for most versions of PC-DMIS here: https://support.hexagonmi.com/s/article/Windows-OS-Compatibility-Listing-for-PC-DMIS
- When you use third-party drivers, you should contact your local Manufacturing Intelligence representative to ensure operating system compatibility.
- Running PC-DMIS inside a Virtual Machine (VM) is supported only if the VM supports OpenGL 3 or higher.
Microsoft .NET Framework
If you do not have Microsoft .NET Framework 4.8 for Windows, the PC-DMIS installer will install it for you.
RAM
4 GB of RAM or higher
- The size of the CAD data file and the tessellation multiplier value used affect the amount of memory needed. These both affect the number of tessellated facets needed to display the model. The smaller the tessellation multiplier value used, the more memory is needed for the facets. For large CAD models, this could cause an “Out of Memory” error. If this occurs, the current PC-DMIS session will be left in an unstable state and should be terminated.
- The default tessellation multiplier value is 1.0. Setting a tessellation multiplier of 0.1 will result in a 10 to 20 percent increase in the memory required over the default value of 1.0. Decreasing the tessellation multiplier further to 0.01 will result in an additional 50 to 65 percent increase in memory required.
1 GB of video RAM
64 GB of RAM Dual-Channel @1063 MHz DDR4-2666 MHz ECC RDIMM memory (for HP-L systems and systems using RS-SQUARED sensors)
CPU
- 2 GHz or higher quad-core processor
- Intel Xeon W-2223 Processor (3.6GHz, 3.9GHz) for HP-L systems
- Intel Xeon Processor E3-1505M (3.00 GHz) for systems using RS-SQUARED sensors
- Intel Core i7 9th Generation or higher (for example, i7-9xxxHx) 6 Cores hyper-threading enabled (for HP-L systems and systems using RS-SQUARED sensors)
Graphics
Compatible with any popular graphics card that meets or exceeds the following suggested minimums:
- GPU Memory 2 GB DDR3*
- 6 GB Memory Bandwidth 29.0 GB/s (for HP-L systems)
- Memory Bandwidth 29.0 GB/s
- CUDA Cores 384
- Open GL 3.0
- NVIDIA Quadro P5000 (4 GB) (for HP-L systems and systems using RS-SQUARED sensors)
- AC or AX type Wi-Fi card for systems using RS-SQUARED sensors
* For an RS4 laser sensor or later model, you need to have a GPU with at least 4 GB DDR3.
The graphics driver must support OpenGL 3.0 or higher. A warning message appears on PC-DMIS start-up if the driver does not support OpenGL 3.0 or if your graphics driver is more than three years old.
Hard drive
2 GB of free hard drive space plus allocated virtual memory of eight times the largest CAD file used.
SSD drive, HDD 10K, or two disks in RAID 0 mode (high-performance hard disk drive).
128 SSD, 128 SSD RAID, 1 TB HDD
Display
Screen resolution of 1920 x 1080 or higher
NOTE: If you use a high resolution monitor under low-light conditions, some PC-DMSI UI elements may be difficult to see. If so, you can try these options:
that provides the best UI visibility. For details on how to change the
PC-DMIS theme, see “Changing the Theme” in the online Help.
• Increase the ambient lighting.
Connectivity
- One Serial port
- Three Ethernet ports. This may be required for specific installations in consideration of local needs, including but not limited to CMM systems where one port is required for controller communications and another for intranet/internet communications.
- Two USB ports
- A properly configured LMS license or a HASP key (a physical USB portlock)
- LAN port with Intel Chipset (for example, I219) (for HP-L systems)
Note: A HASP key does not act as general-purpose data storage; therefore, you cannot use a HASP key to store (download) arbitrary data from a computer. Similarly, you cannot use a HASP key to put (upload) arbitrary data on a computer. Also, only Hexagon applications can read or write to a HASP key; other applications do not have this capability. As a result, you cannot use a HASP key to load and unload data to and from a computer.
Firmware Distributed Controller (FDC) Connection
PC-DMIS establishes a connection with FDC through the following parameters:
• PC-DMIS computer address – 100.0.0.2
• Subnet mask – 255.255.255.0
• Port – 1234
Pcdlrn.exe and PC-DMIS process listens on port 1294.
Some other ports used are 138 and 1900. The port 1900 was listed as a UDP port.
LMS Licensing
The License verification server and ClmAdmin utility for node locked licenses:
https://licensing.wilcoxassoc.com/flexnet/services
The Floating License servers with Flexnet LmAdmin64.exe uses port 27000-27009
on the server. The LocalHost server on port 8090 and older versions defaults to port
8080. You can define these ports when you install license server or through the server
interface. These are only Offline licenses when you are not connected to a machine.
Hexagon Universal Updater
WebSocket URL – ws://webupdater.hexagonmi.com
Server – http://webupdater.hexagonmi.com/v2/db.live
Username – Null
Password – Null
Port – 80
File – updates_v4.20190702090658181.db
Browser
Microsoft Edge, Mozilla Firefox, Google Chrome. We recommend that you keep your browser up to date by installing its latest version
Anti-virus software
Hexagon used the Sophos anti-virus tool to test PC-DMIS 2023.1. The user will need to confirm the performance of any other anti-virus tool.
Solutions for CMMs using RS-232 communications
If you are installing PC-DMIS 2024.1 on a new or existing computer, but you have an older CMM model that uses RS-232 communications, then you will need to install one of these solutions on your computer:
- An external RS-232 serial-to-USB adapter cable plus the serial-to-USB adapter cable driver
- An internal serial adapter card with serial ports
HP-L-10.10 Laser Scanner System
If you need to use the HP-L-10.10 laser scanner system, your laser scanner controller firmware version must be updated to version 0.10.6 Please contact your local Hexagon representative to perform the firmware upgrade.
Contact email for obtaining software installation package: gosoftvip@163.com The resources are sourced from the internet, and this introduction is for learning purposes. If there is any infringement, please contact us for deletion!